Axiom Power Products Private Limited
Axiom Power Products Private Limited
IDA Cherlapally, Hyderabad, Telangana
SEND SMS
SEND EMAIL

Power Supplies For Network Switches

Our product range includes a wide range of network switches power supplies.

Network Switches Power Supplies

Network Switches Power Supplies
  • Network Switches Power Supplies
Get Best Quote
Approx. Price: Rs 480 / PieceGet Latest Price

Product Details:

Minimum Order Quantity500 Piece
Input VoltageAC 100V rms to 270V rms.
BrandAXIOM
WeightApprox 0.5 kgs
EfficiencyLess than 75% at 230V AC input and Fully loaded.
ModelMEFK138100
Dimension111.5 x 47 x 110 mm (WxHxD)
Input Frequency50Hz plus minus 3Hz

OUTPUT CHARACTERISTICS
  • OUTPUTS Equipment supply - 5V at 2.0 Amps max. Battery supply - 13.8V at 1.0A +- 0.20A max. Battery is to be directly floated across the load, however it has separate terminals. Battery is connected to the load through a fuse and reverse polarity protection circuit
  • OUTPUT VOLTAGE REGULATION Load output (with battery disconnected) will be regulated with in +-2%, with battery connected will follow the battery voltage
  • RIPPLE & NOISE Ripple on output load terminal (with battery disconnected) will be less than 150mV. Noise will be less than 300mV Pk - Pk
  • BATTERY CHARGING Battery charging will take place with constant voltage, constant current, Maximum charging current of the battery is limited to 1.0A +- 0.20A.Maximum Charging Voltage is Set at 13.8V +- 2%

 

PROTECTIONS

  • OUTPUT OVER LOAD AND SHORT CKT PROTECTION
  • BATTERY REVERSE POLARITY PROTECTION

 

INDICATIONS

  • MAINS ON INDICATOR Will be ON when AC is available
  • BATTERY ON INDICATOR Will be ON when Battery is supplying power to the Equipment
  • BATTERY LOW INDICATOR Will be ON when Battery voltage is below 10.30V to 10.80V
  • COOLING Free air convection cooling

 

ENVIRONMENT

  • TEMPERATURE Operation -5 to +50 C, Storage -5 to +60 C
  • HUMIDITY Operating 5% RH to 85% RH non - condensing, Storage 5% RH to 95% RH non - condensing

 

PRODUCT SAFETY

  • DI-ELECTRIC VOLTAGE WITHSTAND TEST 1.5 KV AC rms at 50Hz for one minute ( trip current set at 5mA). 1) Between INPUT and CHASIS
  • EARTH GROUND RESISTANCE To be less than 200mW with a test current of 2.0A through GND
Request
Callback
Yes! I am Interested
X

Explore more products



Reach Us
G. Sampath (Business Development Manager)
Plot No. 195/1, 2nd Floor
IDA Cherlapally, Hyderabad- 500051, Telangana, India



Call Us

Share Us

F GT L


Send E-mailSend SMS