Axiom Power Products Private Limited
Axiom Power Products Private Limited
IDA Cherlapally, Hyderabad, Telangana
GST No. 36AAMCA4616K1ZG
TrustSEAL Verified
SEND SMS
SEND EMAIL

Power Supplies For Network Switches

Our product range includes a wide range of network switches power supplies.

Network Switches Power Supplies

Network Switches Power Supplies
  • Network Switches Power Supplies
Get Best Quote
Approx. Price: Rs 480 / PieceGet Latest Price

Product Details:

Minimum Order Quantity500 Piece
Input VoltageAC 100V rms to 270V rms.
BrandAXIOM
WeightApprox 0.5 kgs
EfficiencyLess than 75% at 230V AC input and Fully loaded.
Input Frequency50Hz plus minus 3Hz
Dimension111.5 x 47 x 110 mm (WxHxD)
ModelMEFK138100

OUTPUT CHARACTERISTICS
  • OUTPUTS Equipment supply - 5V at 2.0 Amps max. Battery supply - 13.8V at 1.0A +- 0.20A max. Battery is to be directly floated across the load, however it has separate terminals. Battery is connected to the load through a fuse and reverse polarity protection circuit
  • OUTPUT VOLTAGE REGULATION Load output (with battery disconnected) will be regulated with in +-2%, with battery connected will follow the battery voltage
  • RIPPLE & NOISE Ripple on output load terminal (with battery disconnected) will be less than 150mV. Noise will be less than 300mV Pk - Pk
  • BATTERY CHARGING Battery charging will take place with constant voltage, constant current, Maximum charging current of the battery is limited to 1.0A +- 0.20A.Maximum Charging Voltage is Set at 13.8V +- 2%

 

PROTECTIONS

  • OUTPUT OVER LOAD AND SHORT CKT PROTECTION
  • BATTERY REVERSE POLARITY PROTECTION

 

INDICATIONS

  • MAINS ON INDICATOR Will be ON when AC is available
  • BATTERY ON INDICATOR Will be ON when Battery is supplying power to the Equipment
  • BATTERY LOW INDICATOR Will be ON when Battery voltage is below 10.30V to 10.80V
  • COOLING Free air convection cooling

 

ENVIRONMENT

  • TEMPERATURE Operation -5 to +50 C, Storage -5 to +60 C
  • HUMIDITY Operating 5% RH to 85% RH non - condensing, Storage 5% RH to 95% RH non - condensing

 

PRODUCT SAFETY

  • DI-ELECTRIC VOLTAGE WITHSTAND TEST 1.5 KV AC rms at 50Hz for one minute ( trip current set at 5mA). 1) Between INPUT and CHASIS
  • EARTH GROUND RESISTANCE To be less than 200mW with a test current of 2.0A through GND
Request
Callback
Yes! I am Interested
X

Explore More Product



Reach Us
G. Sampath (Business Development Manager)
Axiom Power Products Private Limited
Plot No. 195/1, 2nd Floor
IDA Cherlapally, Hyderabad - 500051, Telangana, India



Call Us


Send E-mailSend SMS